Store the 2in1 Soprano Titanium Ice Platinum Diode Laser. This ND:YAG machine functions 3 wavelengths (755, 808, 1064nm) for pain-free hair removal.
two-in-one Soprano Titanium Ice 4000W Triple Wavelength Diode & ND:YAG Laser Machine
Obtain Experienced-grade final results While using the Soprano Titanium Ice Platinum, a powerful 2-in-1 technique combining 3-wavelength diode laser technologies for painless hair elimination and also a Q-Switched ND:YAG laser for tattoo elimination and skin rejuvenation. Equipped using a 4000W substantial-ability motor and five-level adjustable cooling technologies, this CE-Licensed device supplies Secure, productive, and long term results for all pores and skin forms and system regions.
Hair Elimination: Triple wavelength (755nm, 808nm, 1064nm) for all pores and skin tones
Skin Correction: Q-Switched ND:YAG for tattoo removal and carbon peeling
Comfort: 5-Level adjustable cooling system to get a painless practical experience
Ability: 4000W superior-energy density with German Diode Arrays
Key Features
three-Wavelength Diode Technological innovation: Integrates 755nm (Alexandrite), 808nm (Speed), and 1064nm (YAG) wavelengths into one applicator to focus on diverse hair depths and constructions simultaneously.
Dual-Purpose Technique: A true 2-in-one workstation showcasing a committed Diode laser for long term hair reduction along with a Q-Switched ND:YAG laser for pigmented lesion therapy and tattoo removing.
Advanced five-Level Cooling: Features the “Titanium Ice” five-stage adjustable cooling technological innovation that keeps the sapphire tip at an exceptional temperature, making certain the treatment continues to be at ease and painless.
Higher Output Effectiveness: Driven by a massive 4000W power offer and German-imported Diode arrays, delivering as many as 2000mj Vitality density for quick and effective medical success.
Substantial Touchscreen Interface: Equipped which has a significant-definition interactive Show for specific Management more than Strength ranges, pulse frequency, and cooling depth across distinctive therapy modes.
Compatibility & Finest Use
Total System Application: Safe and sound and efficient to be used within the face (upper lip, chin), underarms, bikini line, arms, legs, back again, and upper body.
All Skin Styles: The triple wavelength method is get more info built to function correctly on all skin tones (Fitzpatrick scales I-VI) and hair colours, together with fantastic and lightweight hair.
Pores and skin Rejuvenation: Make use of the ND:YAG cope with Using the black doll (carbon) tip for deep pore cleaning, pores and skin whitening, and anti-getting older solutions.
Tattoo & Pigment Removing: Target darkish and coloured inks precisely using the Q-Change frequency for non-invasive elimination check here of tattoos and freckles.
Set up Tips
Drinking water Cooling Setup: This substantial-ability laser demands distilled drinking water for its cooling technique; make sure the h2o tank is filled towards the advised stage right before powering on the machine for the first time.
Manage Link: Meticulously align the pins of your laser handles While using the equipment ports and secure the locking mechanism to make certain steady signal and cooling fluid transmission.
Voltage Verification: The device supports 110V and 220V; guarantee your electricity outlet matches the particular voltage options with the device to forestall electrical hurt.
Parameter Calibration: For brand new end users, it is suggested to start out therapies at the lowest Power settings and steadily improve according to the client’s pores and skin sensitivity and feed-back.
Products Requirements
Model check here Name emszero
Model Selection Titanium two-in-one (4000W)
Laser Wavelengths 755nm, 808nm, 1064nm (Diode) / 532nm, 1064nm, 1320nm (ND:YAG)
Electrical power Output 4000W
Vitality Density Around 2000mj (Adjustable)
Cooling Level website five Degrees Adjustable Sapphire Cooling
Certification CE
Voltage Compatibility AC 110V/220V, 50/60Hz
Packing List
one x Soprano Titanium two-in-1 Main Console (4000W)
one x three-Wavelength Diode Laser Cope with
1 x Q-Switch ND:YAG Laser Handle
three x Specialized ND:YAG Tips (532nm, 1064nm, 1320nm)
one x Electricity Cable & Foot Pedal
1 x Person Guide & Protective Goggles Established
Warnings & Basic safety Notes
Eye Security: Always have on the furnished laser-security goggles during Procedure to avoid long term eye damage from stray laser reflections.
Under no circumstances Run Dry: Do not work the device without filling it with distilled h2o; managing the laser with no performing cooling loop will cause instant interior hardware failure.
Contraindications: Do not use this product on places with open up wounds, Energetic bacterial infections, read more or on individuals who are Expecting or have mild-delicate health-related conditions.
Cooling Servicing: Change the distilled drinking water each three months to make sure The inner pump and laser arrays stay freed from mineral buildup and overheating.